High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Description
Basic Info
Model NO. | DZ-321 |
Max Diameter of Workpiece | 1200mm |
Mass Scope of Workpiece | 1000kg |
Type | Material Testing Machine |
Maxcapacity | >1000KN |
Accuracy Grade | 1 |
Load Way | Electronic Load |
Loading Method | Dynamic Load |
Display | Digital |
Control | Computer Control |
Weight | 100-500Kg |
Power Source | AC220V |
Oil Cylinder Position | Under |
Transport Package | Wooden Packing |
Specification | 20 CBM |
Trademark | OULI |
Origin | China |
HS Code | 8477800000 |
Product Description
High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Summary- High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Moving Die Rubber Rheometer widely used in rubber processing industry, rubber quality control and basic research rubber, For optimize formula of rubber provide accurate data, It can accurately measure the scorch time, rheometer time, sulfide index, the maximum and minimum torque and other parameters.
Main functions-High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Moving Die Rheometer used monolithic rotor control, which include: host, temperature measurement, temperature control, data acquisition and processing, sensors and electrical chains and other components. These measurements, temperature control circuit consists of a temperature control device, platinum resistance, heater composition, capable of automatic tracking power and ambient temperature changes, automatically correct PID parameters to achieve fast and accurate temperature control purposes. Data acquisition system and mechanical linkage to complete the rubber vulcanization process of force torch signal automatic detection, automatic real-time display of temperature and settings. After curing, automatic processing, automatic calculation, print vulcanization curve and process parameters. Show curing time, curing power Ju, also has a variety of audible alert. DZ-321-type non-rotor curing equipment controlled by computer, the computer setting the parameters of the direct control of test parameters rheometer. Display real-vulcanization curve and temperature curve, store test results, different adjustable comparison of test results and in a different color.
Applicable Industries- High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Moving Die Rheometer widely used in rubber industries.
Work Principle-High Quality Rubber Processing Testing Equipment Moving Die Rheometer
The rubber sample into the mold cavity is almost entirely enclosed and maintained at test temperature.
the mold cavity are of two parts, of which the lower part with a small linear reciprocating movement (swing oscillation), oscillatory shear specimen produced strain determination is the reaction torque of the mold cavity (force), this torque (force) depends on the shear modulus of rubber.
Curing test specimens after the start of the shear modulus increases, the computer machine real-time display and record the torque (force), when the torque (force) rose to a stable value or the maximum as well as return to the state, they get a torque ( force) and time curve, that is, curing curve (Figure 1),shape of the curve and test the temperature and plastic material characteristics.
Main Parameters-High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Model | DZ-321 Moving Die Rheometer |
Standard | GB/T16584 IS06502 |
Temperature | room temperature to 200 Centigrade |
Heating-up | 15 Centigrade/min |
Temperature fluctuation | ≤ ±0.3 Centigrade |
Temperature resolution | 0.1 Centigrade |
Torque range | 0-5N.M,0-10N.M,0-20N.M |
Torque resolution | 0.001NM |
Power | 50HZ, ~220V±10% |
Pressure | 0.4Mpa |
Air-pressure requirment | 0.5Mpa--0.65MPa (user prepare the dia 8 trachea) |
Environment temperature | 10 Centigrade--20 Centigrade |
Humidity range | 55--75%RH |
Compressed air | 0.35-0.40Mpa |
Swing frequency | 100r/min (about 1.67HZ) |
Swing angle | ±0.5 Centigrade ,±1 Centigrade , ±3 Centigrade |
Printing | date, time, temperature,vulcanization curve,temperature curve, ML,MH,ts1,ts2,t10 ,t50, Vc1, Vc2 |
Certificate
Package
FAQ
Q1:Why choose Us?
1.More than 20 years history of OULI MACHINE factory.
6-8 years foreign sales experience staff, more efficiency and professional.
Engineers oversea service more than 20 countries .
2.ISO:9001,CE,BV certification approval
3.Service timely, Promise to give solution within 12 hours,Guarantee customer trouble free.
4.Short delivery date, No delay. Accept urgent order for prompt shipment.
Q2:What about delivery date?
It will be according to the quantity of machines. Normally machines will be shipment within 20-30 days after get deposit, No delay.
Accept urgent order for prompt shipment.
Q3:What's the warranty statement?
OULI MACHINE warrants all the products manufactured by OULI MACHINE to free from defects in material and workmanship Under normal use of a period of 12 months or 36months after the date of the original purchase price if repair or replacement is not possible of practical, OULI MACHINE warranty covers ONLY the product itself.
OULI MACHINE will assume no liability for labor costs, installation costs, or other losses.
Your warranty rights will be honored
Only when the product has been installed and used properly as deemed by OULI MACHINE,OULIMACHINE will not repair products damaged by improper use or faulty installation.
Q4:What about OULI oversea service ?
OULI will arrange oversea setting up and training works if customer need .
Customer should pay for accommodation , tickets and salary .
Meanwhile OULI has branches in different areas like north America , Southeast Asia , Brazil etc , etc .
High Quality Rubber Processing Testing Equipment Moving Die Rheometer
Our Contact